Special Note: Feb 27, 2012
This product is end of life. However manufacturer may still have materials to build the part, contact us for more information at 800-813-4218 ext.701
Physical
Ports |
|
10/100Base-T(X) Ports in RJ45 Auto MDI/MDIX |
8 |
Technology |
|
Ethernet Standards |
IEEE 802.3 for 10Base-T, IEEE 802.3u for 100Base-T(X) and 100Base-FX, IEEE 802.3x for Flow control |
MAC Table |
2048 MAC addresses |
Processing | Store-and-Forward |
LED
Indicators |
|
Power Indicator |
Green : Power LED x 2 |
Fault Indicator |
Amber : Indicate PWR1 or PWR2 failure |
10/100TX RJ45 Port Indicator |
Green for port Link/Act. Amber for Duplex/Collision |
Fault contact | |
Relay |
Relay output to carry capacity of 1A at 24VDC |
Power |
|
Redundant Input Power |
Dual DC inputs. 12-48VDC on 6-pin terminal block |
Power Consumption (Typ.) |
4 Watts |
Overload Current Protection |
Present |
Reverse Polarity Protection |
Present |
Physical
Characteristic |
|
Enclosure |
IP-30 |
Dimension (W x D x H) | 26.1(W) x 94.9(D) x 144.3(H) mm (1.03 x 3.74 x 5.68 inch.) |
Environmental |
|
Storage Temperature |
-40 to 85°C (-40 to
185°F) |
Operating Temperature | -40 to 70°C (-40 to 158°F) |
Operating Humidity |
5% to 95% Non-condensing |
Regulatory
approvals |
|
EMI |
FCC Part 15, CISPR (EN55022)
class A |
EMS |
EN61000-4-2 (ESD), EN61000-4-3 (RS), EN61000-4-4 (EFT),
EN61000-4-5 (Surge), EN61000-4-6 (CS), EN61000-4-8, EN61000-4-11 |
Shock |
IEC60068-2-27 |
Free Fall |
IEC60068-2-32 |
Vibration |
IEC60068-2-6 |
Safety |
EN60950 |
Warranty |
2 years |
If you need accessory information for this product, please use our Online Contact Us Form , our industrial sales team is here to help you find the accessories.