TRIPP LITE SU750RTXLCD2UN SMART ONLINE UPS 750VA 675W LCD 120V WEBCARDLX USB DB9 2URM EXT RUN

Mfg Part Number:  SU750RTXLCD2UN  
Image may not reflect the actual item.
Price: $1,380.00 + Free Shipping
Quantity:
In Stock: 26
Last Updated: May 17, 2024
No Sales Tax except these states
, PO and Wire.
Double-Conversion UPS Protects Equipment Against Damage, Downtime and Data Loss

This on-line double-conversion UPS system maintains perfect output by converting AC input to DC, then reconverting UPS output to fully regulated sine wave AC. Constant on-line operation completely isolates sensitive equipment from every power problem on the AC line. The SmartOnline® SU750RTXLCD2UN provides the highest level of power protection and battery backup for education, healthcare, military, government and other mission-critical IT applications where space is limited, but premium power reliability is essential.

Reliable, Expandable Battery Backup Keeps You Operational Through Power Outages

The field-replaceable, hot-swappable VRLA battery modules allow you to work through short power failures and give you enough time to safely save files and shut down your system in case of a prolonged blackout. Zero transfer time between on-line and battery modes maintains continuous operation of connected equipment without interruption or rebooting. Extra runtime is available by connecting up to four optional extended battery modules (BP36RT, sold separately).

Pre-Installed LX Platform Network Management Card Allows Remote Access 24/7

The WEBCARDLXE network interface enables full remote configuration and management, including load shedding, reboots of connected equipment and safe shutdowns. The IP-based Auto Probe feature ensures continuous network uptime by communicating with other network devices, detecting lost connectivity and automatically rebooting IT equipment. Optional EnviroSense2 modules (E2MT, E2MTDO and E2MTHDI, all sold separately) provide a variety of environmental monitoring and control options.

NEMA Outlets Protect Your Connected Components

Eight 5-15R outlets provide connected equipment with pure sine wave AC output and allow you to monitor power consumption down to the outlet group level. Power provided by these outlets is filtered to protect connected equipment against damaging surges and line noise. Four outlets are grouped into two load banks that let you shed non-critical loads to extend runtime for critical loads.

Premium Protection from EMI/RFI Line Noise Helps Your Equipment Perform Better

This UPS system filters out disruptive electromagnetic and radio frequency interference that can inflict hardware damage or data loss. This EMI/RFI filtering also helps your connected components perform better and last longer.

Clear LCD Interface Keeps You Informed at a Glance

The menu-driven front-panel LCD provides detailed alarms and notifications to help diagnose any issues. It provides system status, event logs, battery and power module status, usage analytics, serial number, firmware update info and more. Audible alarms can be disabled through the front menu when the UPS goes to battery power. The LCD rotates to accommodate both rack-mount and tower installation.

Automatically Turns Back On After Power Is Restored

Battery-independent restart ensures automatic UPS power-up without user interaction after lengthy power outages, even after a complete battery discharge.

Main Specification
General Information
Manufacturer Tripp Lite by Eaton
Manufacturer Part Number SU750RTXLCD2UN
Manufacturer Website Address https://tripplite.eaton.com/
Brand Name Tripp Lite by Eaton
Product Line SmartOnline
Product Model SU750RTXLCD2UN
Product Name SmartOnline SU750RTXLCD2UN 750VA Rack-mountable UPS
Product Type Double Conversion Online UPS
Technical Information
Plug/Connector Type NEMA 5-15P
Receptacle Type NEMA 5-15R
Receptacle Detail 6 x NEMA 5-15R
Dataline Protection RJ-11
Dataline Protection RJ-45
Overload Protection Yes
Transfer Time 0 ns
EMI/RFI Noise Filter Yes
Phase Single Phase
Energy Saving Green Energy-Saving
Application/Usage Computer Room
Application/Usage Network Closet
Application/Usage Server
Application/Usage Data Center
Application/Usage Mission Critical Equipment
Power Description
Load Capacity (VA) 750 VA
Load Capacity (Watt) 675 W
Input Voltage 120 V AC
Output Voltage 110 V AC
Output Voltage 100 V AC
Output Voltage 115 V AC
Output Voltage 127 V AC
Input Frequency 60 Hz
Output Frequency 60 Hz
Waveform Type Pure Sine Wave
Surge Energy Rating 570 J
Management
Network Management SNMP/HTTP Remote Monitoring
Alarm Low Battery
Alarm UPS Fault
Alarm Remote Shutdown
Alarm Power Failure
Alarm UPS StartUp
Alarm Overload
Controls/Indicators
Status Indicators

7 Front Panel LEDs Indicator:

  • AC To DC Conversion
  • Battery Mode Operation
  • Inverter Mode
  • ECO Mode Operation
  • Bypass Mode Operation
  • AC Output Status

Front Panel LCD Display:

  • UPS And Site Power Status And Operating Data
  • Configuration Of Voltage
  • Frequency
  • Operating Mode
  • Alarm Function And A Variety Of Additional Options
Interfaces/Ports
Serial Port Yes
EPO Port Yes
USB (HID Compliant) Port Yes
Battery Information
DC System Voltage 24 V DC
Backup/Run Time (Full Load) 4.30 Minute
Backup/Run Time (Half Load) 13.90 Minute
Hot Swappable Yes
Typical Battery Recharge Time 3 Hour
Replaceable Battery Yes
Environmental Conditions
Maximum Operating Elevation 10000 ft
Storage Temperature 5°F (-15°C) - 122°F (50°C)
Maximum Operating Temperature 104°F (40°C)
Sound Emission (A-Weighted) 45 dB(A)
Physical Characteristics
Height 3.5"
Width 17.5"
Depth 12.5"
Rack Height 2U
Form Factor Rack-mountable
Weight (Approximate) 27.60 lb
Miscellaneous
Package Contents
  • 750VA 675W 120V Double-Conversion UPS
  • WEBCARDLXE network management card
  • USB cable
  • DB9 cable
  • Rack-mounting hardware
  • Tower support stands
  • Safety instructions
  • Quick start guide
  • Country of Origin China
    Environmentally Friendly Yes
    Warranty
    Limited Warranty 2 Year
    WARNING:: The plastic used in cable products can expose you to lead and lead components, chemicals known to the State of California to cause cancer, birth defects, or other reproductive harm. For more information go to www.P65Warnings.ca.gov