Following the advance of network technology, the investment that
enterprises make in the network has been continuously growing;
meanwhile, the reliability of network units is progressively
strengthened. Corporations in China are now encountering the flaws in
quality/quantity of electricity, and the defects, covering complex
environment of electric force, harmonic, overload, low voltage, and
disconnection, are intimidating the proper operation of the network and
causing damage to network devices. Also, the disconnection of network
can even lead to the loss of critical data. Fortunately, the Ultimate
series of UPS, provided by PCM, the United States, can deliver optimum
solutions of high scalability and multiple configurations for your web
environment now and future. As the data center of business core, it
particularly requires the high availability of 99.999%; to meet the
requirement, Ultimate of PCM makes the best choice for you.
GENERAL INFORMATION
Model Type ULTIMATE LED
Model Name ULT-1000
Power Rating 1KVA/700W
AC INPUT
AC Input Voltage 100V:76V~130V 110V:80V~138V
115V:83.5V~140V 120V:87V~140V 208V:152V~260V 220V:160V~276V
230V:167V~280V 240V:174V~280V
AC Input Frequency 50 or 60 Hz+/-3 Hz
AC Input Phase Single
AC Input Power factor >= 0.98
AC OUTPUT
AC Output Voltage 100V/110V/115V/120V or
208V/220V/230V/240V
AC Output Frequency 50Hz/60Hz (Auto detection)
AC Output Frequency Stability (+/-0.5%)
AC Output Voltage Regulation (+/-2%)
AC Output Powerfactor 0.7 (lagging)
AC Output Hamonic distortion <3% of T.H.D. at
linear load
AC Output Overload detection 105% for 10 seconds and
130% +/- 10% for 300ms
EFFICIENCY
Field49 > 85%
TRANSFER
Transfer Power failure Recovery 0 ms
Transfer Overload Disappear Auto transfer to UPS
Transfer UPS to By Pass or Vice Versa N/A
NOISE
Noise Level 1m Distance < 45dBA
PROTECTION
Protection Spike 125 Joules
BATTERY
Battery Type Sealed lead acid battery,
free-maintenance
Battery Protection Cut off without draining any
current when battery low
Battery DC Voltage 36V
BACKUP TIME
Battery Backup Time Full Load 8 minutes
Battery Backup Time Half Load 22 minutes
Battery Recharge Time About 8 hours to 90% after
fully discharged
PHYSICAL
Physical Weight kgs Tower 15
Physical Weight lbs Tower (33.0lb)
Physical Weight lbs RM N/A
Physical Dimension mm Tower 145x400x220
Physical Dimension inch Tower (5.7
Physical Dimension mm RM N/A
Physical Dimension inch RM N/A
INDICATOR
LCD Indicators Status Line input (green), inverter
output (green), bypass (yellow), fault (red)
LED LED
ALARM
Alarm Battery Discharge The first warning will beep
every 4 seconds to indicate battery in use. The second warning will
beep every 1 second to signal battery low condition
Alarm UPS Fault Continuous beeping sound
INTERFACE
Interface Dry Contact Provide power management &
diagnostic functions including power status, battery low, schedule UPS
ON/OFF, battery/load level display and more. Compatatible with Windows
95/98/2000/ME/NT/XP, Novell Unix and other popular systems
Interface RS-232 Provide power management &
diagnostic functions including power status, battery low, schedule UPS
ON/OFF, battery/load level display and more. Compatatible with Windows
95/98/2000/ME/NT/XP, Novell Unix and other popular systems
Interface Option N/A
ENVIRONMENT
Environment Temperature 0 deg C ~ 40 deg C
Environment Humidity 0%~95% (Non condensing)
ShowOrder 76