, PO and Wire.
Check here for other accessories.
| Introduction |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
CP-134U
V2
![]() The CP-134U V2 Series of Smart Multiport Serial Boards is used by Industrial Automation system integrators for designing long distance, multi-point PC-based data acquisition applications. On-chip Automatic Data Direction Control for Precision RS-485 Communication RS-485 communication requires precise timing control to enable and disable the line driver. Powered by Moxa's Turbo Serial Engine™ chip that comes with on-chip ADDC™ (Automatic Data Direction Control), sending RS-485 packets over CP-134U V2 is as easy as using RS-232. RS-485 multidrop for up to 31 devices within 1.2 km The CP-134U V2 Universal PCI Multiport Serial Board has 4 RS-422/485 serial ports, each capable of data rates up to 921.6 Kbps. In RS-485 mode, the serial port can connect up to 31 daisychained RS-485 devices within a range of 1.2 km. For long distance RS-485 communication, optional 2 KV isolation protection is available (CP-134U-I V2) to prevent equipment damage. Top Performance with 128-byte FIFO and On-chip H/W,
S/W Flow Control
|
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| Features |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| Specifications |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| Ordering Information |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| Optional Accesories |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
| Power Requirements | |
| Power Consumption | CP-134U: 180 mA @ +5 V CP-134U-I: 850 mA @ +5 V |
| Serial Communication Parameters | |
| Flow Control | RTS/CTS, XON/XOFF |
| Data Bits | 5, 6, 7, 8 |
| Parity | None, Even, Odd, Space, Mark |
| Stop Bits | 1, 1.5, 2 |
| IRQ | Assigned by BIOS |
| I/O Address | Assigned by BIOS |
| Hardware | |
| Connector | DB44 female |
| Bus | 32-bit Universal PCI |
| Comm. Controller | MU860 (16C550C compatible) |
| Performance | |
| Baudrate | 50 bps to 921.6 Kbps |
| Environmental Limits | |
| Operating Temperature | Standard Models: 0 to 55°C (32 to 131°F) Wide Temp. Models: -40 to 85°C (-40 to 185°F) |
| Storage Temperature | -40 to 85°C (-40 to 185°F) |
| Ambient Relative Humidity | 5 to 95% (non-condensing) |
| MTBF (mean time between failures) | |
| Time | 480,209 hrs |
| Database | Telcordia (Bellcore), GB |
| Physical Characteristics | |
| Dimensions | CP-134U: 82.5 x 120 mm (3.24 x 4.72 in) CP-134U-I: 115 x 120 mm (4.52 x 4.72 in) |
| Serial Interface | |
| Serial Standards | 2 x RS-232/422/485, 2 x RS-422/485 |
| Number of Ports | 4 |
| Max. No. of Boards per PC | 4 |
| Serial Line Protection | |
| ESD Protection | 15 KV on the board |
| Optical Isolation | 2 KV (CP-134U-I configured for RS-422/485 only) |
| Serial Signals | |
| RS-485-4w | TxD+(B), TxD-(A), RxD+(B), RxD-(A), GND |
| RS-485-2w | Data+(B), Data-(A), GND |
| RS-422 | TxD+(B), TxD-(A), RxD+(B), RxD-(A), RTS+(B), RTS-(A), CTS+(B), CTS-(A), GND |
| RS-232 | TxD, RxD, RTS, CTS, DTR, DSR, DCD, GND |
| Standards and Certifications | |
| EMI | EN 55022, EN 61000-3-2, EN 61000-3-3, FCC Part 15 Subpart B Class B |
| EMS | EN 55024, IEC 61000-4-2, IEC 61000-4-3, IEC 61000-4-4, IEC 61000-4-5, IEC 61000-4-6, IEC 61000-4-8, IEC 61000-4-11 (DIPS) |
| EMC | CE, FCC |
| Green Product | RoHS, CRoHS, WEEE |
| Driver Support | |
| Operating Systems | Windows 9X/ME/NT/2000, Windows XP/2003/Vista/2008/7 x86/x64, Windows CE 5.0/6.0, Windows XP Embedded, DOS, Linux 2.4, Linux 2.6 x86/x64, FreeBSD 4/5, QNX 6, SCO OpenServer 5/6, UnixWare 7, Solaris 10 x86/x64 |
| Note | Please refer to Moxa's website for the latest driver support information. |
| Warranty | |
| Warranty Period | 5 years |
| Details | See http://www.moxa.com/support/warranty.htm |
WARNING:: The plastic used in cable products can expose you to lead and lead components,