, PO and Wire.
| Scope of Delivery and Accessories | |
| Scope of Delivery | device, terminal block, operating manual |
| Accessories to Order Separately | Rail power supply RPS 30, RPS 80 EEC or RPS 120 EEC, 19" installation frame |
| Interface | |
| Power Supply / Signaling Contact | 1 plug-in terminal block, 5-pin (RS2-5TX, RS2-5TX/FX: no signal contact) |
| 10/100/Base-TX Ports | TP cable, RJ45 sockets, auto-crossing, auto-negotiation, auto-polarity |
| Distance | |
| Twisted Pair (TP) | 0 - 100 m |
| Power | |
| Operating voltage | 24 V DC (-25% to +30%) |
| Current Consumption | Max. 290 mA @ 24VDC |
| Power Consumption | Max. 7,0 W at 24 V DC |
| Service | |
| Diagnostics | LEDs (power, link status, data, error), signal contact / fault relais (24 V DC / 1 A) |
| Environmental | |
| Operating Temperature | 0°C to +60°C |
| Storage Temperature | -25 °C to +70 °C |
| Relative Humidity | 10% to 95% |
| MTBF | 61 years; MIL-HDBK 217F: Gb 25 ºC |
| Mechanical | |
| Dimensions (W x H x D) | 47 mm x 135 mm x 111 mm |
| Mounting | DIN Rail 35 mm |
| Weight | 320 g |
| Protection | IP 20 |
| IEC 60068-2-27 Shock | 15 g, 11 ms duration, 18 shocks |
| IEC 60068-2-6 Vibration | 1 mm, 2 Hz - 13.2 Hz, 90 min.; 0.7g, 13.2 Hz - 100 Hz, 90 min.; 3.5 mm, 3 Hz - 9 Hz, 10 cycles, 1 octave/min.; 1g, 9 Hz - 150 Hz, 10 cycles, 1 octave/min. |
| EMC Interference Immunity | |
| EN 61000-4-2 electrostatic discharge (ESD) | 6 kV contact discharge, 8 kV air discharge |
| EN 61000-4-3 electromagnetic field | 10 V/m (80 - 1000 MHz) |
| EN 61000-4-4 fast transients (burst) | 2 kV power line, 1 kV data line |
| EN 61000-4-5 surge voltage | Power line: 2 kV (line/earth), 1 kV (line/line), 1 kV data line |
| EN 61000-4-6 conducted immunity | 3 V (10 kHz - 150 kHz), 10 V (150 kHz - 80 MHz) |
| Agency Approvals | |
| FCC | FCC CFR47 Part 15 Class A |
| EMI | EN 55022 Class A |
| Redundancy | |
| Redundancy functions | redundant 24 V power supply |
| Germanischer Lloyd | |
| CUL | cUL 508 (E175531)cUL 1604 Class 1 Div 2 (E203960)cUL 60950 (E168643) |
If you need accessory information for this product, please use our Online Contact Us Form , our industrial sales team is here to help you find the accessories.
WARNING:: The plastic used in cable products can expose you to lead and lead components,
chemicals known to the State of California to cause cancer, birth defects, or other reproductive harm.
For more information go to www.P65Warnings.ca.gov