, PO and Wire.
The TCF-142-RM series of serial-to-fiber converters are slide-in
modules that work with the TRC-190 chassis. The modules convert from
the RS-232, RS-422, or RS-485 signal to a fiber optic signal.
| RS-232/422/485 Side | |
| RS-232 Signals | TxD, RxD, SGND |
| RS-422 Signals | TxD+, TxD-, RxD+, RxD-, SGND |
| RS-485-4w Signals | TxD+, TxD-, RxD+, RxD-, SGND |
| RS-485-2w Signals | Data+, Data-, SGND |
| Baudrate | 50 bps to 921.6 Kbps |
| ESD Protection | 15 KV for all signals |
| Optical Fiber | |
| Fiber Connector | SC or ST |
| Cable Requirements | Single-mode:
8.3/125, 8.7/125, 9/125, or 10/125 ?m Multi-mode: 50/125, 62.5/125, or 100/140 ?m |
| Transmission Distance | Single-mode: 40 km Multi-mode: 5 km |
| Wavelength | Single-mode: 1310
nm Multi-mode: 850 nm |
| Tx Output | Single-mode: >
-5 dBm Multi-mode: > -5 dBm |
| RX Sensitivity | Single-mode: -25
dBm Multi-mode: -20 dBm |
| Point-to-Point Transmission | Half-duplex or full-duplex |
| Physical Characteristics | |
| Housing | SPCC |
| Dimensions | 86.8 x 136.5 x 21 mm (3.42 x 5.37 x 0.83 in) |
| Environmental Limits | |
| Operating Temperature | 0 to 60°C (32 to 140°F) |
| Operating Humidity | 5 to 95% RH |
| Storage Temperature | -20 to 75°C (-4 to 158°F) |
| Power Requirements | |
| Input Voltage | 12 VDC |
| Power Consumption | 150 mA @ 12 V |
| Regulatory Approvals | |
| EMS | EN61000-4-2 (ESD),
Criteria A, Level 4 EN61000-4-3 (RS), Criteria A, Level 2 EN61000-4-4 (EFT), Criteria A, Level 3 EN61000-4-5 (Surge), Criteria A, Level 3 EN61000-4-6 (CS), Criteria A, Level 2 EN61000-4-8 (PFMF), Criteria A, Level 3 |
| CE | Class A |
| FCC | Part 15 sub part B Class A |
| Freefall | IEC 60068-2-32 |
| Warranty | |
| Warranty Period | 5 years |
| Power Requirements | |
| Power Consumption | 150 mA @ 12 V |
| Input Voltage | 12 VDC |
| Optical Fiber Side | |
| Wavelength | Single-mode: 1310 nm Multi-mode: 850 nm |
| Transmission Distance | Single-mode: 40 km Multi-mode: 5 km |
| Rx Sensitivity | Single-mode: -25 dBm Multi-mode: -20 dBm |
| Fiber Connector | SC or ST |
| Tx Output | Single-mode: > -5 dBm Multi-mode: > -5 dBm |
| Cable Requirements | Single-mode: 8.3/125, 8.7/125, 9/125, or 10/125 μm Multi-mode: 50/125, 62.5/125, or 100/140 μm |
| Point-to-Point Transmission | Half-duplex or full-duplex |
| Ring Transmission | Half-duplex |
| Environmental Limits | |
| Operating Temperature | 0 to 60°C (32 to 140°F) |
| Storage Temperature | -20 to 75°C (-4 to 158°F) |
| Ambient Relative Humidity | 5 to 95% (non-condensing) |
| MTBF (mean time between failures) | |
| Time | 514,926 hrs |
| Database | Telcordia (Bellcore), GB |
| RS-232/422/485 Side | |
| Connector | DB9 |
| ESD Protection | 15 KV for all signals |
| RS-422 Signals | TxD+, TxD-, RxD+, RxD-, GND |
| RS-485-4w Signals | TxD+, TxD-, RxD+, RxD-, GND |
| RS-232 Signals | TxD, RxD, GND |
| RS-485-2w Signals | Data+, Data-, GND |
| Baudrate | 50 bps to 921.6 Kbps |
| Physical Characteristics | |
| Dimensions | 86.8 x 136.5 x 21 mm (3.42 x 5.37 x 0.83 in) |
| Standards and Certifications | |
| EMI | FCC Part 15 Subpart B Class A |
| EMS | EN 61000-4-2 (ESD) Level 3, EN 61000-4-3 (RS) Level 2, EN 61000-4-4 (EFT) Level 2, EN 61000-4-5 (Surge) Level 2, EN 61000-4-6 (CS) Level 2, EN 61000-4-8 (PFMF) Level 3 |
| EMC | CE, FCC |
| Freefall | IEC 60068-2-32 |
| Green Product | RoHS, CRoHS, WEEE |
| Warranty | |
| Warranty Period | 5 years |
| Details | See http://www.moxa.com/support/warranty.htm |
If you need accessory information for this product, please use our Online Contact Us Form , our industrial sales team is here to help you find the accessories.
WARNING:: The plastic used in cable products can expose you to lead and lead components,
chemicals known to the State of California to cause cancer, birth defects, or other reproductive harm.
For more information go to www.P65Warnings.ca.gov