The Small Three-Phase UPS Solution offered with both VRLA and Lithium-Ion Batteries
For three-phase critical systems, consider the Liebert® ITA2 UPS. It stabilizes power to protect systems and data. Professionals can define the feature set they need to meet their IT performance goals.
Rackmount power made easy
Vertical/Tower Placement
Flexible, Reliable and Functional
The Liebert ITA2 offers a space-saving design to meet your power needs. Options are available to address specific runtimes, distribution and availability requirements.
Save Now, Save Later Compared to Competitive Models
Protect Critical IT Systems From All Key Electrical Threats
General Information | |
Manufacturer | Vertiv |
Manufacturer Part Number | ITA2-05KRT208C |
Manufacturer Website Address | http://www.vertiv.com/ |
Brand Name | Vertiv Liebert |
Product Series | ITA2 |
Product Model | ITA2-05KRT208C |
Product Name | ITA2-05KRT208C 5kVA Rack/Tower UPS |
Product Type | Double Conversion Online UPS |
Technical Information | |
Plug/Connector Type | NEMA L21-20P |
Receptacle Type | NEMA L21-20R |
Overload Protection | Yes |
Cord Length | 6 ft |
Transfer Time | 1.80 ms |
Phase | Three Phase |
Efficiency Detail | 93% (AC Mode) |
Application/Usage | Medical |
Application/Usage | Data Storage |
Application/Usage | Light Industrial Application |
Application/Usage | Security System |
Application/Usage | VoIP |
Application/Usage | Server |
Application/Usage | IT System |
Application/Usage | IT |
Application/Usage | Lab Equipment |
Surge Suppression | Yes |
Power Description | |
Load Capacity (VA) | 5000 VA |
Load Capacity (Watt) | 5000 W |
Input Voltage | 230 V AC |
Input Voltage | 120 V AC |
Input Voltage Range | 96 V AC - 144 V AC |
Output Voltage | 120 V AC |
Output Voltage | 208 V AC |
Input Frequency | 60 Hz |
Input Frequency | 70 Hz |
Input Frequency | 40 Hz |
Input Power Factor | 0.99 |
Output Power Factor | 1 |
Display & Graphics | |
Display | LCD |
Management | |
Network Management | Network Interface Card |
Network Management | BACnet/Modbus |
Battery Information | |
DC System Voltage | 384 V DC |
Battery Characteristics | Sealed Lead Acid, Maintenance-Free, VRLA/Lithium |
Backup/Run Time (Full Load) | 14 Minute |
Backup/Run Time (Half Load) | 26 Minute |
Environmental Conditions | |
Minimum Operating Temperature | 32°F (0°C) |
Maximum Operating Temperature | 122°F (50°C) |
Storage Temperature | 32°F (0°C) - 122°F (50°C) |
Physical Characteristics | |
Height | 5.1" |
Width | 16.9" |
Depth | 25.8" |
Rack Height | 3U |
Form Factor | Rack/Tower |
Mounting Location | Vertical |
Weight (Approximate) | 50.70 lb |
Miscellaneous | |
Certifications & Standards |
|