Tripp Lite Switched ATS / Auto Transfer Switch provides a redundant power option for single-corded network devices. Dual input cords support separate connection to PRIMARY and SECONDARY power sources. The ATS will normally maintain continuous output to all outlets as derived from the primary input cable. If the primary power source becomes unstable or fails altogether, the ATS will switch over to the secondary power source until the primary input is restored and stable. The built-in Java-free HTML5-based LX Platform network interface enables full remote access for PDU status monitoring and email notifications via secure web browser, SNMP, telnet or SSH. It supports 10/100 Mbps auto-sensing for optimum communication with an Ethernet network. Optional EnviroSense2 modules (sold separately) provide a variety of environmental monitoring capabilities. Protocols supported include IPv4, IPv6, HTTP, HTTPS, SMTP, SNMPv1, SNMPv2, SNMPv3, telnet, SSH, FTP, DHCP, BOOTP and NTP. Switched PDU features include individually controllable output receptacles and built-in network interface. Super-fast switchover between primary and secondary power sources occurs within milliseconds. ATS functionality is supported by any two compatible AC power sources, regardless of phase angle, to support a variety of advanced redundant power networking applications. Enables fault tolerant hot-swappable UPS protection when used with a single UPS and fully redundant UPS protection when each cord is connected to a separate UPS system. In a two-UPS environment, the primary input cable must be supported by a full time sine wave UPS with zero transfer time. Tripp Lite SmartOnline series is highly recommended for use as the primary UPS in a two-UPS application. ATS configurations utilizing separate mains circuits, backup generators and even separate utility power grid feeds are fully supported. On-board ATS processor constantly evaluates power quality on both input sources to prevent transfer to the secondary source when unavailable or of lower quality than the primary source. Front input LED's display primary or secondary power availability.
More from the Manufacturer
Main Specification
General Information |
Manufacturer |
Eaton Corporation |
Manufacturer Part Number |
PDUMH20ATNET |
Manufacturer Website Address |
http://www.eaton.com |
Brand Name |
Tripp Lite by Eaton |
Product Model |
PDUMH20ATNET |
Product Name |
PDUMH20ATNET PDU Switched ATS 120V 20A 16 Outlet |
Product Type |
PDU |
Technical Information |
PDU Type |
Switched |
Plug/Connector Type |
NEMA L5-20P |
Plug/Connector Detail |
2 x NEMA L5-20P |
Receptacle Type |
NEMA 5-15/20R |
Receptacle Detail |
16 x NEMA 5-15/20R |
Power Description |
Input Voltage |
120 V AC |
Output Voltage |
120 V AC |
Power Rating (VA) |
2400 VA |
Management |
Management |
- Integrated Automatic Transfer Switch (ATS) allows PDU to operate from secondary input source when primary input fails
- Sequential outlet power-on prevents inrush-related equipment interaction on startup
- Programmable or real-time monitoring and outlet power control via secure web/network interface
|
Physical Characteristics |
Color Family |
Black |
Product Color |
Black |
Mount Type |
Rack-mountable |
Rack Height |
1U |
Number of Cord/Cable |
2 |
Height |
1.8" |
Width |
1.8" |
Depth |
14.5" |
Weight (Approximate) |
12.20 lb |
Miscellaneous |
Package Contents |
- PDUMH20ATNET PDU Switched ATS 120V 20A 16 Outlet
- PDU with attached L5-20P input power cord
- Detachable C19 to NEMA L5-20P 12 ft/3.6m power cord for optional secondary input
- Two NEMA L5-20R to NEMA 5-20P plug adapters
- User manual with warranty information
|
Certifications & Standards |
- 60950
- Class A
- TAA Compliant
|
Country of Origin |
Taiwan |
TAA Compliant |
Yes |
Environmentally Friendly |
Yes |
Environmental Compliance |
Restriction of Hazardous Substances (RoHS) |
Warranty |
Limited Warranty |
2 Year |
General Information |
Product |
-
|
Number of Outlets |
16
|
Surge Energy Rating |
-
|
Data Line Protection |
-
|
Cord Length |
-
|
Mounting Style |
-
|
Output Voltage |
-
|
Current Rating |
-
|
MODEL- PDUMH20ATNET VENDOR- TRIPPLITE
FEATURES- Switched, Metered PDU with ATS
Power Distribution Unit with dual-input Auto Transfer Switching,
individual outlet control and SNMP network interface!
1U rackmount PDU with digital current monitoring display; 20A 120V
capacity with 16 NEMA 5-15/20R outlets; Connects to NEMA 5-15R
and locking L5-20R receptacle; Integrated Automatic Transfer Switch
(ATS) allows PDU to operate from secondary input source when
primary input fails; Sequential outlet power-on prevents inrush-
related equipment interaction on startup; Programmable or real-time
monitoring and outlet power control via secure web/network
interface.
Tripp Lite's 120V 20A metered PDU system with Automatic Transfer
Switching (ATS) is an 16 outlet PDU with a digital display to
indicate total PDU power consumption in amps. Outlets are
sequentially turned on at 250 milliscond intervals when the PDU is
first energized from an unpowered state to prevent inrush-related
equipment interaction on startup. Installed web/network monitoring
card enables remote power monitoring and control. Remotely displays
status of input power, load capacity, and outlet power status via
secure network or web browswer interface. Offers individual outlet
control to power on, off, or cycle AC output to regain control of
locked-up servers and other network devices. Load ramping and
shedding provides automatic power management. Supports notification
and logging of input power status, event notification, output power
and load conditions. Supports 1U rackmount installation in a 2 or 4
post racks. Included are 16 NEMA 5-15/20R outlets, and optional-use
dual cords for auto- transfer switching (ATS) options. Each input
plug supports 5-20P and L5-20P input.
Optional integrated ATS is available for use when two separately
derived input power sources are available. The attached power cord
serves as the primary AC input cable, while the included detachable
power cord serves as the optional-use secondary AC input
connection. The PDU system passes the primary input power through
to connected equipment whenever line voltage and frequency levels
are normal. If the primary input source goes outside of these
tolerances or fails altogether, the ATS will automatically switch
all PDU output to the secondary line sourced input power (when
available) to maintain continuous operation of connected loads
without reboots or service interruptions. Once the primary power
source is restored, the PDU will automatically switch back to
primary sourced input power. The dual input cabling can be
configured for UPS maintenance bypass of standard UPS systems or to
create a redundant dual-UPS power source for a critical, single-
corded network device. Front AC input LED's show what input AC
source is being utilized by the PDU.
Includes PDU with attached L5-20P input power cord, Detachable C19 to
NEMA L5-20P 12 ft / 3.6m power cord for optional secondary input,
Two NEMA L5-20R to NEMA 5-20P plug adapters, User manual with
warranty information.
* 120V 20A metered PDU system with Automatic Transfer Switch (ATS).
* Dual input cords, one attached (primary) and one optional-use detachable
cord (secondary).
* Included cordsets support 5-20P and L5-20P plug-in connections via secure
adapters.
* Front panel digital ammeter displays power consumption in amps
* Web/Network monitoring card enables remote power monitoring and control
of power to each outlet.
* Sixteen built-in NEMA 5-15/20R output receptacles
* Optional ATS function enables setup for hot-swappable UPS maintenance
bypass, dual UPS protection or dual AC input redundancy for critical
single-corded network hardware.
* Small 1U rackmount format installs in only one rack space with a maximum
installed depth of 14.5 inches.
* Also supports 0U vertical mounting in the cable managment area of many
rack enclosures.
* Individually controlled outlets provide load management to networked
equipment.
* Sequential outlet turn on eliminates power up in-rush of connected
devices on initial start-up.
-- SPECIFICATIONs -----------------------------------
OUTPUT - Volt Amp Capacity : 20A/2400VA
Nominal voltage : 120V
Outlets : (16) NEMA 5-15/20R
Customized load
management
receptacles : (16) individually controlled load
management receptacles.
INPUT - Input amps : 20A
Connection type : (2) NEMA L5-20P with 2 NEMA 5-20P plug
adapters.
Cord length : Both input cables are 12 ft / 3.6m -
the cables each terminate to a L5-20P
locking plug on the input side. Two
included 6 inch plug adapters convert
the locking plugs to NEMA 5-20P
plugs.
Recommended
electrical service: 120V 20A, dedicated line recommended
LEDs, ALARMS & SWITCHES-
Front panel LEDs : 16 front panel LEDs display power on -
off status for each outlet, plus
2 LEDs for power status on each input
line cord. Digital Current Meter
displays output power consumption in
amps.
MATERIAL - Steel
FORM FACTOR - 1U rackmount
COMMUNICATION- SNMP compatibility: Yes, via pre-installled SNMPWEBCARD.
Provides remote monitoring, outlet control, and automatic
power management configurations.
APPROVALS - Tested to UL60950-1 (USA) and CAN/CSA C22.2 No. 60950-1-03
(Canada), RoHS Compliant.
DIMENSIONS - 17.5"w x 1.75"h x 14.5"d WT.- 12.2 lbs.
www.tripplite.com
Cable Management
$72.21
$56.99
$84.99
Power Cords
$13.50
$12.99
$20.14
$17.18
$21.65
$30.48
$44.99
$19.10
$149.99
$40.89
$18.85
$23.94
$23.49
$27.09
$38.49
Proximity Sensors
$56.71
Services
$118.67
Temperature & Humidity Sensors
$133.17
$162.44