, PO and Wire.
The Server Technology® PRO2 Switched POPS PDU provides control of outlet power and local LED input current monitoring, allowing IT personnel to determine safe levels of loading on a per-phase basis while installing equipment into the rack/cabinet. The integral PIPS® and POPS® technology provides billing-grade accurate measurement of current, voltage, active power, apparent power, power factor, crest factor, and accumulated energy at the input and at each output. These power data points, along with temperature and humidity measurements (provided via optional probes), are accessible through the built-in Web and CLI interfaces as well as through SNMP. The PRO2 Switched POPS "Primary" PDU can be connected to as many as three (with optional module) PRO2 Switched POPS "Link" PDUs to extend the network access to the redundant or secondary power feed without the risks of a daisy chain linking configuration.
| General Information | |
| Manufacturer | Legrand Group |
| Manufacturer Part Number | C2XG24SN-0AJN5D6 |
| Manufacturer Website Address | http://www.legrand.us |
| Brand Name | Server Technology |
| Product Series | PRO2 |
| Product Name | PRO2 24-Outlets PDU |
| Product Type | PDU |
| Technical Information | |
| PDU Type | Switched |
| Plug/Connector Type | IEC C20 100-240V Inlet |
| Receptacle Type | CX |
| Receptacle Type | IEC 60320 C13 |
| Receptacle Detail | 6 x CX |
| Receptacle Detail | 18 x IEC 60320 C13 |
| Protection Type | Fuse |
| Protection Type | Circuit Protection |
| Protection Type | Circuit Breaker |
| Protection Type | Branch Circuit |
| Locking Receptacles | P-Lock |
| Features | LED Display |
| Power Description | |
| Input Voltage | 230 V AC |
| Input Voltage | 120 V AC |
| Input Voltage Range | 120 V AC - 240 V AC |
| Output Voltage | 208 V AC |
| Output Voltage | 230 V AC |
| Power Rating (Watt) | 3840 W |
| Input Current | 20 A |
| Input Frequency | 60 Hz |
| Circuit Breaker | Yes |
| Management | |
| Remote Outlet Switching | Yes |
| Interfaces/Ports | |
| Network (RJ-45) | Yes |
| Physical Characteristics | |
| Mount Type | Cabinet-mountable |
| Mount Type | Rack-mountable |
| Rack Height | 2U |
| Height | 3.5" |
| Width | 17.2" |
| Depth | 17.5" |
| Environmental Conditions | |
| Minimum Operating Temperature | 32°F (0°C) |
| Maximum Operating Temperature | 140°F (60°C) |
| Minimum Storage Temperature | -40°F (-40°C) |
| Maximum Storage Temperature | 185°F (85°C) |
| Minimum Operating Humidity | 8% |
| Maximum Operating Humidity | 90% |
| Miscellaneous | |
| Application/Usage | IT Equipment |
| Application/Usage | Server Rack/Cabinet |
WARNING:: The plastic used in cable products can expose you to lead and lead components,
chemicals known to the State of California to cause cancer, birth defects, or other reproductive harm.
For more information go to www.P65Warnings.ca.gov