, PO and Wire.
The Server Technology® PRO1 Switched PDU provides control of outlet power and local LED input current monitoring, allowing IT personnel to determine safe levels of loading on a per-phase basis while installing equipment into the rack/cabinet. The integral PIPS® technology provides billing grade accurate measurement of current, voltage, active power, apparent power, power factor, crest factor, and accumulated energy at the input. These power data points, along with temperature and humidity measurements (provided via optional probes), are accessible through the built-in Web and CLI interfaces as well as through SNMP. The PRO1 Switched "Primary" PDU can be connected to as many as three (with optional module) PRO1 Switched "Link" PDUs to extend the network access to the redundant or secondary power feed without the risks of a daisy chain linking configuration.
| General Information | |
| Manufacturer | Legrand Group |
| Manufacturer Part Number | SEV-4541D |
| Manufacturer Website Address | http://www.legrand.us |
| Brand Name | Server Technology |
| Product Series | PRO1 |
| Product Name | PRO1 24-Outlets PDU |
| Product Type | PDU |
| Technical Information | |
| PDU Type | Switched |
| Phase | Three Phase |
| Plug/Connector Type | IEC 60320 C20 |
| Receptacle Type | IEC 60320 C13 |
| Receptacle Type | IEC 60320 C19 |
| Receptacle Detail | 6 x IEC 60320 C19 |
| Receptacle Detail | 18 x IEC 60320 C13 |
| Protection Type | Fuse |
| Protection Type | Double Pole |
| Protection Type | Branch Circuit |
| Protection Type | Circuit Protection |
| Locking Receptacles | P-Lock |
| Features | LED Display |
| Load Capacity (Watt) | 3600 W |
| Power Description | |
| Input Voltage | 230 V AC |
| Output Voltage | 230 V AC |
| Input Current | 16 A |
| Input Frequency | 60 Hz |
| Circuit Breaker | Yes |
| Management | |
| Management |
|
| Interfaces/Ports | |
| Network (RJ-45) | Yes |
| Physical Characteristics | |
| Mount Type | Cabinet-mountable |
| Mount Type | Button Mount |
| Mount Type | Rack-mountable |
| Rack Height | 0U |
| Height | 69" |
| Width | 1.8" |
| Depth | 2.3" |
| Environmental Conditions | |
| Minimum Operating Temperature | 32°F (0°C) |
| Maximum Operating Temperature | 122°F (50°C) |
| Minimum Storage Temperature | -22°F (-30°C) |
| Maximum Storage Temperature | 176°F (80°C) |
| Miscellaneous | |
| Application/Usage | IT Equipment |
| Application/Usage | Server Rack/Cabinet |
| UL Listed | Yes |
WARNING:: The plastic used in cable products can expose you to lead and lead components,