TRIPP LITE  Selector

Tripp Lite - Isolator IS1800HG 6 outlets Transformer

Mfg Part Number:  IS1800HG  
Image may not reflect the actual item.
Price: $764.69
Quantity:
In Stock: 68
Last Updated: Jun 19, 2025
No Sales Tax except these states
, PO and Wire.

Isolator Series UL60601-1 Listed Medical Grade Isolation Transformers offer line isolation, continuous noise filtering and enhanced common mode surge suppression. An internal low-impedance isolation transformer component offers 100% isolation from the input AC line. Full UL60601-1 medical-grade listing with hospital-grade plug and outlet receptacles makes Isolator medical-grade transformers ideal for protection of sensitive electronic equipment in patient-care areas. Faraday shield reduces the cumulative leakage current of the Isolator and connected equipment to levels less than 100 microamps. Secondary neutral-to-ground bonding virtually eliminates common mode noise, providing an isolated neutral-ground reference for sensitive equipment, and an inexpensive alternative to dedicated circuits and site electrical upgrades. Removes EMI/RFI noise, utility switching transients and harmonics generated by other on-site loads and utility or lightning related surge conditions. Additional surge suppression components placed at the line input and output combined with full line isolation offer continuous filtering of a full range of power line noise in all modes. Active transformer filtering provides continuous common-mode noise rejection with no wearable parts. Unique ability to reduce surges in the worst of power environments to harmless levels. Reduces 6000V IEE

More from the Manufacturer

Main Specification
General Information
Manufacturer Eaton Corporation
Manufacturer Part Number IS1800HG
Manufacturer Website Address https://tripplite.eaton.com/
Brand Name Tripp Lite by Eaton
Product Model IS1800HG
Product Name Isolator IS1800HG 6 outlets Transformer
Product Type Isolation Transformer
Technical Information
Power Rating 1800 VA
Output Receptacle Type NEMA 5-20R
Output Receptacle Detail 6 x NEMA 5-20R
Power Description
Input Voltage 120 V AC
Maximum Line Current 15 A
Physical Characteristics
Form Factor Small Tower Format
Height 7.8"
Width 8.3"
Depth 12.3"
Miscellaneous
Additional Information
  • Hospital Grade Outlets and Plug
  • 20A circuit breaker
  • Total Harmonic Distortion: Less than 1%
  • Rugged all-metal unit housing
  • Cooling Method: Convection
  • Noise Suppression Rating: 35-65 DB
  • Suppression Joule Rating: 1190 (1020 input / 170 output)
  • Efficiency: 96%
Package Contents
  • Isolator IS1800HG 6 outlets Transformer
  • IS1800HG Isolation Transformer
  • NEMA5-15P replacement plug
  • User manual with warranty information
Certifications & Standards
  • UL
  • cUL
Country of Origin Taiwan
TAA Compliant Yes
Warranty
Limited Warranty 2 Year
General Information
Product Type Isolation Transformers
Power Rating 1.8 kVA
Primary Voltage Rating 120 V
Secondary Voltage Rating -
Secondary Current Rating -
Mounting Style -
Primary Winding -
Secondary Winding -
Length 7.75 in
Width 209.55 mm
Height 196.85 mm
Outside Diameter -
Tripp Lite Isolator series UL2601-1 listed Hospital Grade isolation transformers offer line isolation, continuous noise filtering and enhanced common mode surge suppression. Internal low-impedance isolation transformer component offers 100% isolation from the input AC line. Full UL2601-1 medical grade listing with hospital-grade plug and outlet receptacles makes Isolator Hospital Grade transformers ideal for the protection of sensitive electronic equipment in patient-care areas. Isolation transformer with Faraday shield reduces the cumulative leakage current of the Isolator and connected equipment to levels below 300 microamps. Secondary neutral to ground bonding eliminates common mode noise, providing an isolated ground reference for sensitive equipment and an inexpensive alternative to the installation of dedicated circuits and site electrical upgrades. Removes EMI/RFI noise, utility switching transients, and harmonics generated by other on-site loads and utility or lightning related surge conditions. Additional surge suppression components placed at the line input and output combined with full line isolation offers continuous filtering of a full range of power line noise in all modes. Active transformer filtering offers continuous common-mode noise rejection with no wearable parts, uniquely able to reduce surges in the worst of power environments to harmless levels. Reduces 6000V IEEE587 Cat A&B ring wave and combination wave test surges to only 0.5V common mode. Model IS1800HG includes 6 widely spaced NEMA5-15R hospital grade output receptacles, a 6 ft power cord, hospital grade input plug, circuit breaker overload protection and lighted power switch. Rugged all-metal unit housing ships ready for upright tower or wallmount placement in any industrial, medical, office or network environment.

Features:
Tripp Lite's IS1800HG Hospital Grade isolation transformer offers line isolation, continuous noise filtering and enhanced common mode surge suppression

Internal low-impedence isolation transformer with Faraday shield offers 100% isolation from the input AC line

Full UL2601-1 medical grade listing with hospital-grade plug and outlet receptacles makes Isolator Hospital Grade transformers ideal for the protection of sensitive electronic equipment in patient-care areas. -Reduces the cumulative leakage current of the Isolator and connected equipment to levels below 300 microamps.

Secondary neutral to ground bonding eliminates common mode noise, providing an isolated ground reference for sensitive equipment

Serves as an inexpensive alternative to the installation of dedicated circuits and site electrical upgrades

Removes EMI/RFI noise, utility switching transients, load generated harmonics and ground loops

Additional surge suppression components placed at the line input and output combined with full line isolation offers continuous filtering of a full range of power line noise in all modes

Active transformer filtering offers continuous common-mode noise rejection with no wearable parts, uniquely able to reduce surges in the worst of power environments to harmless levels

Reduces 6000V IEEE587 Cat A&B ring wave and combination wave test surges to only 0.5V common mode

Includes 6 widely spaced NEMA5-20R hospital grade output receptacles, a 6 ft power cord, hospital grade input plug, circuit breaker overload protection and lighted power switch

Ships with NEMA5-20P input plug installed, package includes NEMA5-15P user installable hospital grade replacement plug for compatiblity with common 15A wall receptacle

Rugged all-metal unit housing ships ready for upright tower or wallmount placement in any industrial, medical, office or network environment

2-year limited product warranty
Specifications:

Nominal Voltage / Frequency    120V / 60Hz
VA / Watt Capacity    1800
Amp Capacity    15A at 120V AC
Transformer Type    Hospital Grade, low impedence transformer-based line isolation transformer
Total Harmonic Distortion    less than 1%
Over Current Protection    Yes, 20A circuit breaker
Output Receptacle Qty / Type    6 NEMA 5-20R Hospital Grade Outlets
Input Plug Type    NEMA 5-20P Hospital Grade Plug
Input Cord Length    6.00 ft. / 1.83 m
Leakage Current    less than 300 microamps
Efficiency    96%
Suppression Joule Rating    1190 (1020 input / 170 output)
Noise Suppression Rating    35-65 DB
Surge Test Conditions    Per ANSI/IEEE C62.41 - IEEE587 Cat. A & B test waveforms
Let-through Voltage (Ring Wave)    L-N: 20V L-G: 20V N-G: 0.5V
Let-through Voltage (Combination Wave)    L-N: 250V L-G: 250V N-G: 0.5V
Cooling Method    Convection
Form Factor    Small tower format
Unit Dimensions (HWD/in.)    7.75 x 8.25 x 12.25
Shipping Weight    58.00 lbs. / 26.31 kg
Warranty    2-year limited product warranty
Approvals    UL (UL Series AGIS1800YWN), cUL

WARNING:: The plastic used in cable products can expose you to lead and lead components, chemicals known to the State of California to cause cancer, birth defects, or other reproductive harm. For more information go to www.P65Warnings.ca.gov