, PO and Wire.
| Technology: | |
| Standards | IEEE 802.3 for 10BaseT IEEE 802.3u for 100BaseT(X), 100BaseFX |
| Interface: | |
| RJ45 Ports | 10/100BaseT(X) |
| Fiber Port(s) | 100BaseFX (SC/ST/LC connectors) |
| LED Indicators | PTC-101-HV series: PWR1, Fiber Link, 10/100M (TP port) PTC-101-LV series: PWR1, PWR2, Fiber Link, 10/100M (TP port) |
| Alarm Contact | One relay output with current carrying capacity of 1 A @ 24 VDC |
| Optical Fiber | |
![]() |
|
| Power Requirements: | |
| Overload Current Protection | 1.6 A (protects against two signals shorted together) |
| Connection | Removable terminal block |
| Reverse Polarity Protection | Present |
| DIP Switches | |
![]() |
|
| Input Voltage | |
![]() |
|
| Physical Characteristics: | |
| Housing | Aluminum, IP30 protection |
| Dimensions | 122.5 x 90 x 20 mm (4.82 x 3.54 x 0.79 in) |
| Environmental Limits: | |
| Operating Temperature | -40 to 85°C (-40 to 185°F) |
| Storage Temperature | -40 to 85°C (-40 to 185°F) |
| Operating Humidity | 5 to 95% RH |
| Agency Approvals: | |
| EMI | FCC Part 15, CISPR (EN55022) class A |
| EMS | EN61000-4-2 Edition 1.2: 2001-04 (Level 4) EN61000-4-3: 1995+A1: 2001 IEC 61000-4-3: 2002+A1: 2002 (Level 3) EN61000-4-4: 2004 (Level 4) EN61000-4-5: 2001-04 (Level 4) EN61000-4-6: 2004-11 (Level 3) EN61000-4-8: 2001-03 (Level 5) EN61000-4-11: 2004-03 (Criteria B) |
| Safety | UL 60950-1 |
| Rail Traffic | EN50155/EN50121-4 |
| Power Automation | IEC 61850-3, IEEE 1613 |
| Warranty: | |
| Warranty Period | 5 years |
| Interface | |
| DIP Switches | |
| Fiber Ports | 100BaseFX (SC/ST/LC connectors) |
| LED Indicators | PWR1, PWR2, Fiber Link, 10/100M (TP port) |
| Alarm Contact | One relay output with current carrying capacity of 1 A @ 24 VDC (LV model only) |
| RJ45 Ports | 10/100BaseT(X) |
| Power Requirements | |
| Overload Current Protection | 1.6 A (protects against two signals shorted together) |
| Reverse Polarity Protection | Protects against V+/V- reversal |
| Input Voltage | |
| Connection | Removable terminal block |
| Technology | |
| Standards | IEEE 802.3 for 10BaseT IEEE 802.3u for 100BaseT(X), 100BaseFX |
| Environmental Limits | |
| Operating Temperature | -40 to 85°C (-40 to 185°F) |
| Storage Temperature | -40 to 85°C (-40 to 185°F) |
| Conformal Coating | Available upon request |
| Ambient Relative Humidity | 5 to 95% (non-condensing) |
| MTBF (mean time between failures) | |
| Time | 1,211,613 hrs |
| Database | Telcordia (Bellcore), GB |
| Physical Characteristics | |
| Weight | Product only: 690 g Packaged: 875 g |
| Dimensions | 152.15 x 123.46 x 66.65 mm (5.99 x 4.86 x 2.62 in) |
| Housing | Metal, IP30 protection |
| Standards and Certifications | |
| EMI | FCC Part 15 Subpart B Class A, EN 55022 Class A |
| Safety | UL 60950-1 |
| Rail Traffic | EN 50155, EN 50121-4 |
| Note | Refer to the "Environmental Type Tests" table below for more detailed information. |
| Vibration | IEC-61850-3, IEC-60870-2-2 |
| EMS | EN 61000-4-2 (ESD) Level 4, EN 61000-4-3 (RS) Level 3, EN 61000-4-4 (EFT) Level 4, EN 61000-4-5 (Surge) Level 4, EN 61000-4-6 (CS) Level 3, EN 61000-4-8 (PFMF) Level 5, EN 61000-4-11 |
| EMC | CE, FCC |
| Power Automation | IEC 61850-3, IEEE 1613 |
| Freefall | IEC 60068-2-32 |
| Green Product | RoHS, CRoHS, WEEE |
| Warranty | |
| Warranty Period | 5 years |
| Details | See www.moxa.com/warranty |
WARNING:: The plastic used in cable products can expose you to lead and lead components,
chemicals known to the State of California to cause cancer, birth defects, or other reproductive harm.
For more information go to www.P65Warnings.ca.gov