, PO and Wire.
| Comm. Controller | MU860 (16C550C compatible) |
| Bus | 32-bit Universal PCI |
| Connector | DB62 female |
| Number of Ports | 8 |
| Serial Standards | CP-118U RS-232/422/485 CP-138U RS-422/485 |
| ESD Protection | 15 KV on the board |
| Operating Systems | Windows (2000, XP/2003/Vista/2008 x86/x64, 9X/ME/NT), Windows CE 5.0/6.0, Windows XP Embedded, DOS, Linux 2.4, Linux 2.6 (x86/x64), FreeBSD 4/5, QNX 6, SCO Open Server 5/6, UnixWare 7 |
| Dimensions | 82 x 135 mm (3.22 x 5.31 in) |
| Operating Temperature | Standard Models 0 to 55°C
(32 to 131°F) Wide Temp. Models -40 to 85°C (-40 to 185°F) |
| Power Requirements | |
| Power Consumption | CP-118U: 240 mA @ +5 V (RS-232), 300 mA @ +5 V (RS-422) CP-138U: 135 mA @ +5V (RS-422) |
| Serial Communication Parameters | |
| Flow Control | RTS/CTS, XON/XOFF |
| Data Bits | 5, 6, 7, 8 |
| Parity | None, Even, Odd, Space, Mark |
| Stop Bits | 1, 1.5, 2 |
| IRQ | Assigned by BIOS |
| I/O Address | Assigned by BIOS |
| Hardware | |
| Connector | DB62 female |
| Bus | 32-bit Universal PCI |
| Comm. Controller | MU860 (16C550C compatible) |
| Performance | |
| Baudrate | 50 bps to 921.6 Kbps |
| Environmental Limits | |
| Operating Temperature | Standard Models: 0 to 55°C (32 to 131°F) Wide Temp. Models: -40 to 85°C (-40 to 185°F) |
| Storage Temperature | -40 to 85°C (-40 to 185°F) |
| Ambient Relative Humidity | 5 to 95% (non-condensing) |
| MTBF (mean time between failures) | |
| Time | 1,147,210 hrs |
| Database | Telcordia (Bellcore), GB |
| Physical Characteristics | |
| Dimensions | 82 x 135 mm (3.22 x 5.31 in) |
| Serial Interface | |
| Serial Standards | CP-118U: RS-232/422/485 CP-138U: RS-422/485 |
| Number of Ports | 8 |
| Max. No. of Boards per PC | 4 |
| Serial Line Protection | |
| ESD Protection | 15 KV on the board |
| Serial Signals | |
| RS-485-4w | TxD+(B), TxD-(A), RxD+(B), RxD-(A), GND |
| RS-485-2w | Data+(B), Data-(A), GND |
| RS-422 | TxD+(B), TxD-(A), RxD+(B), RxD-(A), GND |
| RS-232 | TxD, RxD, RTS, CTS, DTR, DSR, DCD, GND |
| Standards and Certifications | |
| EMI | EN 55022, EN 61000-3-2, EN 61000-3-3, FCC Part 15 Subpart B Class B |
| EMS | EN 55024, IEC 61000-4-2, IEC 61000-4-3, IEC 61000-4-4, IEC 61000-4-5, IEC 61000-4-6, IEC 61000-4-8, IEC 61000-4-11 (DIPS) |
| EMC | CE, FCC |
| Green Product | RoHS, CRoHS, WEEE |
| Driver Support | |
| Operating Systems | Windows 9X/ME/NT/2000, Windows XP/2003/Vista/2008/7 x86/x64, Windows CE 5.0/6.0, Windows XP Embedded, DOS, Linux 2.4, Linux 2.6 x86/x64, FreeBSD 4/5, QNX 6, SCO Open Server 5/6, UnixWare 7, Solaris 10 x86/x64 |
| Note | Please refer to Moxa's website for the latest driver support information. |
| Warranty | |
| Warranty Period | 5 years |
| Details | See http://www.moxa.com/support/warranty.htm |
WARNING:: The plastic used in cable products can expose you to lead and lead components,
chemicals known to the State of California to cause cancer, birth defects, or other reproductive harm.
For more information go to www.P65Warnings.ca.gov