| Comm. Controller | MU860 (16C550C compatible) |
| Bus | 32-bit Universal PCI |
| Connectors | DB25 female |
| Serial Interface | |
| Serial Standards | RS-232/422/485 |
| Number of Ports | 2 |
| Number of Boards | 4 |
| ESD Protection | 15 KV on the board |
| Isolation | 2 KV (CP-112UL-I only) |
| Performance | |
| Baudrate | 50 bps to 921.6 Kbps |
| Serial Communication Parameters | |
| Data Bits | 5, 6, 7, 8 |
| Stop Bits | 1, 1.5, 2 |
| Parity | None, Even, Odd, Space, Mark |
| Flow Control | RTS/CTS, XON/XOFF |
| I/O Address | Assigned by BIOS |
| IRQ | Assigned by BIOS |
| Serial Signals | |
| RS-232 | TxD, RxD, RTS, CTS, DTR, DSR, DCD, GND |
| RS-422 | TxD+(B), TxD-(A), RxD+(B), RxD-(A), GND |
| RS-485-4w | TxD+(B), TxD-(A), RxD+(B), RxD-(A), GND |
| RS-485-2w | Data+(B), Data-(A), GND |
| Driver Support | |
| Operating Systems | Windows (2000, XP/2003/Vista/2008 x86/x64), Linux 2.4, Linux 2.6 (x86/x64) |
| Physical Characteristics | |
| Dimensions | 64.4 x 120 mm (2.53 x 4.72 in) |
| Environmental Limits | |
| Operating Temperature | Standard Models: 0
to 55°C (32 to 131°F) Wide Temp. Models: -40 to 85°C (-40 to 185°F) |
| Operating Humidity | 5 to 95% RH |
| Storage Temperature | -40 to 85°C (-40 to 185°F) |
| Regulatory Approvals | |
| EMS | EN55022, EN55024, EN61000-3-2, EN61000-3-3, IEC 61000-4-2, IEC 61000-4-3, IEC 61000-4-4, IEC 61000-4-5, IEC 61000-4-6, IEC 61000-4-8, IEC 61000-4-11 (DIPS) |
| FCC | Part 15 Class B |
| Power Requirements | |
| Power Consumption | CP-112UL: 175 mA @
5 VDC CP-112UL-I: 290 mA @ 5 VDC |
| Warranty | |
| Warranty Period | 5 years |
| Power Requirements | |
| Power Consumption | CP-112UL: 175 mA @ 5 VDC CP-112UL-I: 290 mA @ 5 VDC |
| Serial Communication Parameters | |
| Flow Control | RTS/CTS, XON/XOFF |
| Data Bits | 5, 6, 7, 8 |
| Parity | None, Even, Odd, Space, Mark |
| Stop Bits | 1, 1.5, 2 |
| IRQ | Assigned by BIOS |
| I/O Address | Assigned by BIOS |
| Hardware | |
| Connector | DB25 female |
| Bus | 32-bit Universal PCI |
| Comm. Controller | MU860 (16C550C compatible) |
| Performance | |
| Baudrate | 50 bps to 921.6 Kbps |
| Environmental Limits | |
| Operating Temperature | Standard Models: 0 to 55°C (32 to 131°F) Wide Temp. Models: -40 to 85°C (-40 to 185°F) |
| Storage Temperature | -40 to 85°C (-40 to 185°F) |
| Ambient Relative Humidity | 5 to 95% (non-condensing) |
| MTBF (mean time between failures) | |
| Time | 219,971 hrs |
| Database | Telcordia (Bellcore), GB |
| Physical Characteristics | |
| Dimensions | 64.4 x 120 mm (2.53 x 4.72 in) |
| Serial Interface | |
| Serial Standards | RS-232/422/485 |
| ESD Protection | 15 KV on the board |
| Number of Ports | 2 |
| Max. No. of Boards per PC | 4 |
| Optical Isolation | 2 KV (CP-112UL-I only) |
| Serial Signals | |
| RS-485-4w | TxD+(B), TxD-(A), RxD+(B), RxD-(A), GND |
| RS-485-2w | Data+(B), Data-(A), GND |
| RS-422 | TxD+(B), TxD-(A), RxD+(B), RxD-(A), GND |
| RS-232 | TxD, RxD, RTS, CTS, DTR, DSR, DCD, GND |
| Standards and Certifications | |
| EMI | EN 55022, EN 61000-3-2, EN 61000-3-3, FCC Part 15 Subpart B Class B |
| EMS | EN 55024, IEC 61000-4-2, IEC 61000-4-3, IEC 61000-4-4, IEC 61000-4-5, IEC 61000-4-6, IEC 61000-4-8, IEC 61000-4-11 (DIPS) |
| EMC | CE, FCC |
| Green Product | RoHS, CRoHS, WEEE |
| Driver Support | |
| Operating Systems | Windows 2000, Windows XP/2003/Vista/2008/7 x86/x64, DOS, Linux 2.4, Linux 2.6 x86/x64, Solaris 10 x86/x64 |
| Note | Please refer to Moxa's website for the latest driver support information. |
| Warranty | |
| Warranty Period | 5 years |
| Details | See http://www.moxa.com/support/warranty.htm |

WARNING:: The plastic used in cable products can expose you to lead and lead components,
chemicals known to the State of California to cause cancer, birth defects, or other reproductive harm.
For more information go to www.P65Warnings.ca.gov