, PO and Wire.
| Hardware | |
| Comm. Controller | MOXA UART MU860 (16C550C comaptible) |
| Connectors | DB44 Female |
| Interface | |
| Bus | 32-bit Universal PCI |
| Number of Ports | 4 (only one IRQ required) |
| Max No. of Boards | 4 |
| RS-232 | TxD, RxD, RTS, CTS, DTR, DSR, DCD, GND |
| RS-422 | TxD+(B), TxD-(A), RxD+(B), RxD-(A), RTS+(B),RTS-(A), CTS+(B), CTS-(A), GND |
| 4-wire RS-485 | TxD+(B), TxD-(A), RxD+(B), RxD-(A),GND |
| 2-wire RS-485 | Data+(B), Data-(A), GND |
| Performance | |
| Baud Rate | 50 bps to 921.6 Kbps |
| Configuration | |
| I/O Address/IRQ | BIOS assigned |
| Data Bits | 5, 6, 7, 8 |
| Stop Bits | 1, 1.5, 2 |
| Parity | None, Even, Odd, Space, Mark |
| Flow Control | RTS/CTS, XON/XOFF |
| Operating Systems | |
| OS Supported | Windows Vista (X86 & X64), Windows NT/2000/XP/2003, Windows 95/98/ME, Linux 2.4/2.6 (Redhat, SuSe), FreeBSD 4.x, Windows XP Embedded, DOS |
| Power and Environment | |
| Optical Isolation | 2 KV (CP-134U-I) |
| Operating Temperature | 0 to 55°C |
| Storage Temperature | -20 to 85°C (-4 to 185°F) |
| Humidity | 5 to 95% RH |
| ESD Protection | Embedded 15KV ESD Protection |
| Dimensions (W x D) | CP-134U: 120 x 82.5 mm (4.72 x 3.24 in) CP-134U-I: 120 x 115 mm (4.72 x 4.52 in) |
| Regulatory Aprrovals | EN55022 Class B, EN55024, EN6100-3-2, EN61000-3-3, FCC Part 15 Class B |
| Warranty | 5 years |
| Power Consumption | |
| CP-134U | 180 mA (+5V) |
| CP-134U-I | 850 mA (+5V) |
| Power Requirements | |
| Power Consumption | CP-134U: 180 mA @ +5 V CP-134U-I: 850 mA @ +5 V |
| Serial Communication Parameters | |
| Flow Control | RTS/CTS, XON/XOFF |
| Data Bits | 5, 6, 7, 8 |
| Parity | None, Even, Odd, Space, Mark |
| Stop Bits | 1, 1.5, 2 |
| IRQ | Assigned by BIOS |
| I/O Address | Assigned by BIOS |
| Hardware | |
| Connector | DB44 female |
| Bus | 32-bit Universal PCI |
| Comm. Controller | MU860 (16C550C compatible) |
| Performance | |
| Baudrate | 50 bps to 921.6 Kbps |
| Environmental Limits | |
| Operating Temperature | Standard Models: 0 to 55°C (32 to 131°F) Wide Temp. Models: -40 to 85°C (-40 to 185°F) |
| Storage Temperature | -40 to 85°C (-40 to 185°F) |
| Ambient Relative Humidity | 5 to 95% (non-condensing) |
| MTBF (mean time between failures) | |
| Time | 480,209 hrs |
| Database | Telcordia (Bellcore), GB |
| Physical Characteristics | |
| Dimensions | CP-134U: 82.5 x 120 mm (3.24 x 4.72 in) CP-134U-I: 115 x 120 mm (4.52 x 4.72 in) |
| Serial Interface | |
| Serial Standards | 2 x RS-232/422/485, 2 x RS-422/485 |
| Number of Ports | 4 |
| Max. No. of Boards per PC | 4 |
| Serial Line Protection | |
| ESD Protection | 15 KV on the board |
| Optical Isolation | 2 KV (CP-134U-I configured for RS-422/485 only) |
| Serial Signals | |
| RS-485-4w | TxD+(B), TxD-(A), RxD+(B), RxD-(A), GND |
| RS-485-2w | Data+(B), Data-(A), GND |
| RS-422 | TxD+(B), TxD-(A), RxD+(B), RxD-(A), RTS+(B), RTS-(A), CTS+(B), CTS-(A), GND |
| RS-232 | TxD, RxD, RTS, CTS, DTR, DSR, DCD, GND |
| Standards and Certifications | |
| EMI | EN 55022, EN 61000-3-2, EN 61000-3-3, FCC Part 15 Subpart B Class B |
| EMS | EN 55024, IEC 61000-4-2, IEC 61000-4-3, IEC 61000-4-4, IEC 61000-4-5, IEC 61000-4-6, IEC 61000-4-8, IEC 61000-4-11 (DIPS) |
| EMC | CE, FCC |
| Green Product | RoHS, CRoHS, WEEE |
| Driver Support | |
| Operating Systems | Windows 9X/ME/NT/2000, Windows XP/2003/Vista/2008/7 x86/x64, Windows CE 5.0/6.0, Windows XP Embedded, DOS, Linux 2.4, Linux 2.6 x86/x64, FreeBSD 4/5, QNX 6, SCO OpenServer 5/6, UnixWare 7, Solaris 10 x86/x64 |
| Note | Please refer to Moxa's website for the latest driver support information. |
| Warranty | |
| Warranty Period | 5 years |
| Details | See http://www.moxa.com/support/warranty.htm |
WARNING:: The plastic used in cable products can expose you to lead and lead components,
chemicals known to the State of California to cause cancer, birth defects, or other reproductive harm.
For more information go to www.P65Warnings.ca.gov