, PO and Wire.
| RS-232/422/485 Side | |
| Connector(s) | Terminal Block |
| RS-232 Signals | Tx, Rx, GND |
| RS-422 Signals | TxD+, TxD-, RxD+, RxD-, GND |
| RS-485-4w Signals | TxD+, TxD-, RxD+, RxD-, GND |
| RS-485-2w Signals | Data+, Data-, GND |
| Baudrate | 300 bps to 921.6 Kbps |
| ESD Protection | 15 KV for all signals |
| Optical Fiber | |
| Fiber Connector | SC or ST |
| Cable Requirements | Single-mode:
8.3/125, 8.7/125, 9/125, or 10/125 ?m Multi-mode: 50/125, 62.5/125, or 100/140 ?m |
| Transmission Distance | Single-mode: 40 km Multi-mode: 5 km |
| Wavelength | Single-mode: 1310
nm Multi-mode: 820 nm |
| Tx Output | Single-mode: >
-5 dBm Multi-mode: > -5 dBm |
| RX Sensitivity | Single-mode: -25
dBm Multi-mode: -20 dBm |
| Point-to-Point Transmission | Half-duplex or full-duplex |
| Ring Transmission | Half-duplex |
| Physical Characteristics | |
| Enclosure | Aluminum (1 mm) |
| Dimensions | Without ears: 67 x
100 x 22 mm (2.64 x 3.94 x 0.87 in) With ears: 90 x 100 x 22 mm (3.54 x 3.94 x 0.87 in) |
| Environmental Limits | |
| Operating Temperature | Standard Models: 0
to 60°C (32 to 140°F) Wide Temp. Models: -40 to 75°C (-40 to 167°F) |
| Operating Humidity | 5 to 95% RH |
| Storage Temperature | -40 to 85°C (-40 to 185°F) |
| Power Requirements | |
| Input Voltage | 12 to 48 VDC |
| Power Consumption | 140 mA @ 12 V |
| Voltage Reversal Protection | Protects against V+/V- reversal |
| Power Line Protection | 2 KV Burst (EFT),
EN61000-4-4 2 KV Surge, EN61000-4-5 |
| Over Current Protection | 1.1 A (protects against two signals shorted together) |
| Regulatory Approvals | |
| EMI | EN55022 1998, Class B |
| EMS | EN61000-4-2 (ESD),
Criteria A, Level 2 EN61000-4-3 (RS), Criteria A, Level 2 EN61000-4-4 (EFT), Criteria A, Level 2 EN61000-4-5 (Surge), Criteria A, Level 3 EN61000-4-6 (CS), Criteria A, Level 2 EN61000-4-11(DIPS), Criteria A, Level 2 |
| UL/CUL | UL60950-1 |
| TUV | EN60950-1 |
| FCC | Part 15 Subclass B |
| Warranty | |
| Warranty Period | 5 years |
| Power Requirements | |
| Power Consumption | 140 mA @ 12 V |
| Input Voltage | 12 to 48 VDC |
| Voltage Reversal Protection | Protects against V+/V- reversal |
| Over Current Protection | 1.1 A (protects against two signals shorted together) |
| Power Line Protection | 2 KV Burst (EFT), EN61000-4-4 2 KV Surge, EN61000-4-5 |
| Optical Fiber Side | |
| Wavelength | Single-mode: 1310 nm Multi-mode: 850 nm |
| Transmission Distance | Single-mode: 40 km Multi-mode: 5 km |
| Rx Sensitivity | Single-mode: -25 dBm Multi-mode: -20 dBm |
| Fiber Connector | SC or ST |
| Tx Output | Single-mode: > -5 dBm Multi-mode: > -5 dBm |
| Cable Requirements | Single-mode: 8.3/125, 8.7/125, 9/125, or 10/125 μm Multi-mode: 50/125, 62.5/125, or 100/140 μm |
| Point-to-Point Transmission | Half-duplex or full-duplex |
| Ring Transmission | Half-duplex |
| Environmental Limits | |
| Operating Temperature | Standard Models: 0 to 60°C (32 to 140°F) Wide Temp. Models: -40 to 75°C (-40 to 167°F) |
| Storage Temperature | -40 to 75°C (-40 to 167°F) |
| Ambient Relative Humidity | 5 to 95% (non-condensing) |
| MTBF (mean time between failures) | |
| Time | 780,480 hrs |
| Database | Telcordia (Bellcore), GB |
| RS-232/422/485 Side | |
| Connector | Terminal Block |
| ESD Protection | 15 KV for all signals |
| RS-422 Signals | TxD+, TxD-, RxD+, RxD-, GND |
| RS-485-4w Signals | TxD+, TxD-, RxD+, RxD-, GND |
| RS-232 Signals | Tx, Rx, GND |
| RS-485-2w Signals | Data+, Data-, GND |
| Baudrate | 50 bps to 921.6 Kbps |
| Physical Characteristics | |
| Weight | 320 g |
| Dimensions | Without ears: 67 x 100 x 22 mm (2.64 x 3.94 x 0.87 in) With ears: 90 x 100 x 22 mm (3.54 x 3.94 x 0.87 in) |
| Housing | Aluminum (1 mm) |
| Standards and Certifications | |
| EMI | FCC Part 15 Subpart B Class B, EN 55022 Class B |
| Safety | UL 60950-1 |
| EMS | EN 61000-4-2 (ESD) Level 3, EN 61000-4-3 (RS) Level 2, EN 61000-4-4 (EFT) Level 2, EN 61000-4-5 (Surge) Level 2, EN 61000-4-6 (CS) Level 2, EN 61000-4-8 (SFMF) Level 1 |
| EMC | CE, FCC |
| Green Product | RoHS, CRoHS, WEEE |
| Warranty | |
| Warranty Period | 5 years |
| Details | See http://www.moxa.com/support/warranty.htm |
WARNING:: The plastic used in cable products can expose you to lead and lead components,
chemicals known to the State of California to cause cancer, birth defects, or other reproductive harm.
For more information go to www.P65Warnings.ca.gov