8-outlet basic metered 1U PDU (Basic Metered series). Distributes power to 8 NEMA 5-20R outlets through an IEC-320 C20 inlet, single-phase 100-120V, 20A max (16A derated), 1.9 kVA. A front-panel 7-segment LED shows real-time aggregate current (RMS) at the input for at-a-glance load balancing during installation. As a basic metered unit it has no outlet switching, no network connection, and no software setup, so it is fully self-contained. Steel enclosure. Ships with a detachable C19 to NEMA 5-15P power cord (6 ft), a mounting bracket set with, and a quick-start and safety guide. UL/CSA 62368-1:2019 (3rd Ed.) Listed, cTUVus.
8-outlet switched Pro+ 1U ATS PDU (SynLink SP series) adding dual-input redundancy to single-corded equipment. The automatic transfer switch fails over from the primary to the secondary (B-side) source on an outage without loss of power and reverts when primary returns. Eight NEMA 5-20R outlets are fed from dual IEC-320 C20 inlets rated 20A (16A derated) at 100-120V, 1.9 kVA. Each outlet is individually switched for remote reboot and sequenced startup, and is metered per outlet for current RMS plus active power; the inlet reports bank V/A/Hz/W/PF/VA/kWh. Manage over RJ45 Ethernet via web UI, REST API, SNMP v1/v2/v3, SSH, Telnet, SMTP, Syslog, NTP, and DHCP, with out-of-band access through the RS-232 (RJ45) console-server port and USB-serial (FTDI). Two sensor ports accept temperature/humidity probes, a full-color LCD eases setup, and the unit adds built-in surge suppression, AutoPing, outlet scheduling, event triggers/webhooks, and relay health monitoring.
16-outlet switched Pro+ 2U PDU with built-in Automatic Transfer Switch (SynLink SP series). Dual inlets accept A-side and B-side feeds and switch automatically on source loss without dropping the load. Twelve IEC C13 and four IEC C19 outlets at 100-240V, 20A (16A derated). Each outlet is individually relay-switched for remote on/off/reboot and sequenced startup, with per-outlet current RMS and active power metering plus inlet energy metering (V/A/Hz/W/PF/VA/kWh). Manage over HTTP/HTTPS, SSH, Telnet, SMTP, SNMP v1/v2/v3, Syslog, REST API, DHCP, NTP, and Ping, with AutoPing reboot, programmable event triggers, and a color LCD. Two environmental sensor ports (SPA-0010) accept temperature/humidity probes, and an RS-232 (RJ45) serial console server port plus USB-serial (FTDI) give out-of-band access. Centrally managed via the Synaccess Central Management Portal (CMP). Includes two detachable A/B power cords, a mounting bracket set, and quick-start and safety guides.
16-outlet basic metered 2U PDU (Basic Metered series). Distributes power to 12 IEC C13 and 4 IEC C19 outlets through an attached NEMA L6-30P plug (8 ft cord), single-phase 208-240V, 30A max (24A derated), 5.8 kVA. Two 2-pole branch circuit breakers (UL498) provide overload protection. A front-panel 7-segment LED shows real-time current (RMS) per 8-outlet group for at-a-glance load balancing during installation. As a basic metered unit it has no outlet switching, no network connection, and no software setup, so it is fully self-contained. Steel enclosure with rack-mount brackets. Ships with a quick-start and safety guide. UL/CSA 62368-1:2019 (3rd Ed.) Listed, cTUVus.
24-outlet switched Pro+ 0U PDU (SynLink SP series): 20 IEC C13 and 4 IEC C19 outlets, fed by a NEMA L6-30P inlet, single-phase 208-240V, 30A (24A derated), 5.8 kVA. Per-outlet relay switching for remote reboot plus per-outlet current metering (current RMS, active power) and inlet/bank energy monitoring (V, A, Hz, W, VA, PF, kWh). Manage over 10/100 Ethernet via web UI, SNMP v1/2/3, HTTP(S) API, SSH, Telnet, and Syslog, with RJ45 RS-232 and USB-serial (FTDI) out-of-band console access. Two ports accept temperature/humidity sensors, a full-color LCD aids local setup, AutoPing and programmable event triggers automate reboots, and two 2-pole circuit breakers add branch overload protection. Includes a mounting bracket set. UL/CSA 62368-1:2019 listed, cTUVus. Supports centralized fleet management via the Synaccess Central Management Portal (CMP).
16-outlet switched Pro+ 2U PDU (SynLink SP series). Sixteen IEC C13 outlets on a NEMA L5-30P 30A input (24A derated) at 100-120V, protected by two single-pole circuit breakers. Each outlet is individually relay-switched for remote on/off/reboot and sequenced startup, with per-outlet current RMS, voltage RMS, and active power metering plus inlet energy metering (V/A/Hz/W/VA/PF/kWh) and relay health monitoring. Manage over HTTP/HTTPS, SSH, Telnet, SMTP, SNMP v1/v2/v3, Syslog, REST API, DHCP, NTP, and Ping, with AutoPing reboot, programmable event triggers, and a color LCD. Two environmental sensor ports (SPA-0010) accept temperature/humidity probes, and an RS-232 (RJ45) serial console server port plus USB-serial (FTDI) CLI give out-of-band access. Centrally managed via the Synaccess Central Management Portal (CMP). Includes a mounting bracket set and quick-start and safety guides. 3-year warranty. UL/CSA 62368-1:2019 listed, cTUVus.
24-outlet monitored 0U PDU (SynLink SP series): 20 IEC C13 and 4 IEC C19 outlets, fed by a NEMA L6-30P inlet, single-phase 208-240V, 30A (24A derated), 5.8 kVA. Inlet, bank, and per-outlet energy monitoring (V, A, Hz, W, VA, PF, kWh), with no outlet switching. Manage over 10/100 Ethernet via web UI, SNMP v1/2/3, HTTP(S) API, SSH, Telnet, and Syslog, with RJ45 RS-232 and USB-serial (FTDI) out-of-band console access. Two ports accept temperature/humidity sensors, a full-color LCD aids local setup, programmable event triggers raise alerts, and two 2-pole circuit breakers add branch overload protection. Includes a mounting bracket set. UL/CSA 62368-1:2019 listed, cTUVus. Supports centralized fleet management via the Synaccess Central Management Portal (CMP).
5-outlet switched netBooter 1U PDU (B-series). 5x individually switched C13 outlets fed by an IEC-320 C14 inlet, 100-240V, 50-60 Hz, 15A (12A derated), 2.9 kVA, single-phase. Each outlet powers on, off, or reboots remotely. AutoPing watches device IPs and auto power-cycles a hung load; outlet scheduling runs daily/weekly routines. Managed over 10 Mbps Ethernet via HTTP, Telnet, SMTP, DHCP, NTP, and BootP, with up to 3 local accounts. Front-panel status LEDs indicate outlet, power, and network state. A USB-A serial port (FTDI) provides direct PDU CLI access (not a serial console server). Ships with a C13-to-NEMA 5-15P cord and a mounting bracket set. UL/CSA 62368-1 (2nd Ed.) Listed, cTUVus.
24-outlet basic metered 0U vertical PDU (Basic Metered series). Distributes power to 24 NEMA 5-20R outlets through an IEC-320 C20 inlet, single-phase 100-120V, 20A max (16A derated), 1.9 kVA. A 7-segment LED shows real-time current (RMS) per 12-outlet group for at-a-glance load balancing during installation. As a basic metered unit it has no outlet switching, no network connection, and no software setup, so it is fully self-contained. Steel enclosure with a 0U toolless mounting kit. Ships with a detachable C19 to NEMA 5-15P power cord (6 ft) and a quick-start and safety guide. UL/CSA 62368-1:2019 (3rd Ed.) Listed, cTUVus.
16-outlet monitored 2U PDU (SynLink SP series, feature set D). Sixteen NEMA 5-20R outlets fed by an IEC-320 C20 inlet at 100-120V, 20A (16A derated), with inlet energy metering (V/A/Hz/W/VA/PF/kWh) plus per-outlet and per-circuit monitoring, and no outlet switching. Manage over HTTP/HTTPS, SSH, Telnet, SMTP, SNMP v1/v2/v3, Syslog, REST API, DHCP, NTP, and Ping, with AutoPing alerting, programmable event triggers, and a color LCD that shows power data locally. Two environmental sensor ports (SPA-0010) accept temperature/humidity probes, and an RS-232 (RJ45) serial console server port plus USB-serial (FTDI) give out-of-band access. Centrally managed via the Synaccess Central Management Portal (CMP). Includes a detachable C19-to-NEMA-5-15P cord (6 ft), a mounting bracket set, and quick-start and safety guides. UL/CSA 62368-1:2019 listed, cTUVus.
8-outlet switched netBooter 1U PDU (DU-series). 8x individually switched C13 outlets fed by an IEC-320 C14 inlet, 100-240V, 50-60 Hz, 15A (12A derated), 2.9 kVA, single-phase. Each outlet powers on, off, or reboots remotely. AutoPing watches device IPs and auto power-cycles a hung load; outlet scheduling runs daily/weekly routines. Managed over 10/100 Ethernet via HTTP/HTTPS, Telnet, SNMP v1/v2, SMTP, Syslog, DHCP, and NTP (no SSH), with local accounts. A whole-PDU inlet current RMS meter reads out on a 7-digit LED display, and a sensor port accepts the optional TS-0300 temperature probe. A USB-A serial port (FTDI) provides direct PDU CLI access. Ships with a C13-to-NEMA 5-15P cord and a mounting bracket set. UL/CSA 62368-1 (2nd Ed.) Listed, cTUVus.
16-outlet switched Pro+ 2U PDU with built-in Automatic Transfer Switch (SynLink SP series). Dual inlets accept A-side and B-side feeds and switch automatically on source loss without dropping the load. Sixteen IEC C13 outlets at 100-240V, 20A (16A derated). Each outlet is individually relay-switched for remote on/off/reboot and sequenced startup, with per-outlet current RMS and active power metering plus inlet energy metering (V/A/Hz/W/PF/VA/kWh). Manage over HTTP/HTTPS, SSH, Telnet, SMTP, SNMP v1/v2/v3, Syslog, REST API, DHCP, NTP, and Ping, with AutoPing reboot, programmable event triggers, and a color LCD. Two environmental sensor ports (SPA-0010) accept temperature/humidity probes, and an RS-232 (RJ45) serial console server port plus USB-serial (FTDI) give out-of-band access. Centrally managed via the Synaccess Central Management Portal (CMP). Includes two detachable A/B power cords, a mounting bracket set, and quick-start and safety guides.
8-outlet switched netBooter 1U PDU (DX-series). 8x individually switched NEMA 5-15R outlets fed by an IEC-320 C14 inlet, 100-120V, 50-60 Hz, 15A (12A derated), 1.4 kVA, single-phase. Each outlet powers on, off, or reboots remotely, with AutoPing auto power-cycling, outlet scheduling, and event triggers/webhooks. Managed over 10/100 Ethernet via HTTP/HTTPS, SSH, Telnet, SNMP v1/v2/v3, REST API, Webhooks, SMTP, Syslog, DHCP, NTP, and IPv6, with local accounts plus LDAP, RADIUS, and Okta. Supports centralized fleet management via the Synaccess Central Management Portal (CMP). A whole-PDU inlet current RMS meter reads out on a 7-digit LED display, and a sensor port accepts the optional SPA-0010 probe. An RJ45 RS-232 port serves as both PDU CLI and a serial console server to an attached device. Ships with a C13-to-NEMA 5-15P cord and a mounting bracket set. UL/CSA 62368-1 (2nd Ed.) Listed, cTUVus.
20-outlet switched netBooter 0U vertical PDU (DU-series). 20x individually switched C13 outlets fed by an IEC-320 C20 inlet, 100-240V, 50-60 Hz, 20A (16A derated), 3.8 kVA, single-phase. Each outlet powers on, off, or reboots remotely. AutoPing watches device IPs and auto power-cycles a hung load; outlet scheduling runs daily/weekly routines. Managed over 10/100 Ethernet via HTTP/HTTPS, Telnet, SNMP v1/v2, SMTP, Syslog, DHCP, and NTP (no SSH), with local accounts. A whole-PDU inlet current RMS meter reads out on a 7-digit LED display, and a sensor port accepts the optional TS-0300 temperature probe. A DB9 RS-232 port provides direct PDU CLI access (not a serial console server). Ships with a C19-to-NEMA 5-15P cord and a mounting bracket set. UL/CSA 62368-1 (2nd Ed.) Listed, cTUVus.
10-outlet switched netBooter 0U vertical PDU (DU-series). 10x individually switched NEMA 5-15R outlets fed by an IEC-320 C20 inlet, 100-120V, 50-60 Hz, 20A (16A derated), 1.9 kVA, single-phase. Each outlet powers on, off, or reboots remotely. AutoPing watches device IPs and auto power-cycles a hung load; outlet scheduling runs daily/weekly routines. Managed over 10/100 Ethernet via HTTP/HTTPS, Telnet, SNMP v1/v2, SMTP, Syslog, DHCP, and NTP (no SSH), with local accounts. A whole-PDU inlet current RMS meter reads out on a 7-digit LED display, and a sensor port accepts the optional TS-0300 temperature probe. A DB9 RS-232 port provides direct PDU CLI access (not a serial console server). Ships with a C19-to-NEMA 5-15P cord and a mounting bracket set. UL/CSA 62368-1 (2nd Ed.) Listed, cTUVus.
5-outlet switched netBooter 1U PDU (DX-series). 5x individually switched C13 outlets fed by an IEC-320 C14 inlet, 100-240V, 50-60 Hz, 15A (12A derated), 2.9 kVA, single-phase. Each outlet powers on, off, or reboots remotely, with AutoPing auto power-cycling, outlet scheduling, and event triggers/webhooks. Managed over 10/100 Ethernet via HTTP/HTTPS, SSH, Telnet, SNMP v1/v2/v3, REST API, Webhooks, SMTP, Syslog, DHCP, NTP, and IPv6, with local accounts plus LDAP, RADIUS, and Okta. Supports centralized fleet management via the Synaccess Central Management Portal (CMP). A whole-PDU inlet current RMS meter reads out on a 7-digit LED display, and a sensor port accepts the optional SPA-0010 probe. A DB9 RS-232 port serves as both PDU CLI and a serial console server to an attached device. Ships with a C13-to-NEMA 5-15P cord and a mounting bracket set. UL/CSA 62368-1 (2nd Ed.) Listed, cTUVus.
16-outlet switched Pro+ 2U PDU (SynLink SP series) for 208V/240V deployments. Twelve IEC C13 and four IEC C19 outlets on an attached NEMA L6-30P plug at 30A (24A derated), delivering 4.9 kVA at 208V or 5.8 kVA at 240V, protected by two 2-pole circuit breakers. Each outlet is individually relay-switched for remote on/off/reboot and sequenced power-on, with per-outlet current RMS and active power metering plus 2-bank and combined-inlet energy metering (V/A/Hz/W/PF/VA/kWh) for capacity planning. Manage over HTTP/HTTPS, SSH, Telnet, SMTP, SNMP v1/v2/v3, Syslog, REST API, DHCP, NTP, and Ping, with AutoPing reboot, programmable event triggers, and a front-panel LCD. Two environmental sensor ports (SPA-0010) accept temperature/humidity probes, and an RS-232 (RJ45) serial console server port plus USB-serial (FTDI) give out-of-band access. Centrally managed via the Synaccess Central Management Portal (CMP). Includes a mounting bracket set and quick-start and safety guides.
24-outlet basic metered 0U vertical ATS PDU (Basic Metered series). Distributes power to 24 IEC C13 outlets through dual IEC-320 C20 inlets, single-phase 100-240V, 20A max (16A derated), 3.8 kVA. Built-in automatic transfer switch provides A/B source failover across the two inlets. A 7-segment LED shows real-time current (RMS) per 12-outlet group for at-a-glance load balancing during installation. As a basic metered unit it has no outlet switching, no network connection, and no software setup, so it is fully self-contained. Steel enclosure with a 0U toolless mounting kit. Ships with two detachable A/B power cords and a quick-start and safety guide.
10-outlet switched netBooter 0U vertical PDU (DU-series). 10x individually switched NEMA 5-15R outlets fed by an IEC-320 C20 inlet, 100-120V, 50-60 Hz, 20A (16A derated), 1.9 kVA, single-phase. Each outlet powers on, off, or reboots remotely. AutoPing watches device IPs and auto power-cycles a hung load; outlet scheduling runs daily/weekly routines. Managed over 10/100 Ethernet via HTTP/HTTPS, Telnet, SNMP v1/v2, SMTP, Syslog, DHCP, and NTP (no SSH), with local accounts. A whole-PDU inlet current RMS meter reads out on a 7-digit LED display, and a sensor port accepts the optional TS-0300 temperature probe. A USB-A serial port (FTDI) provides direct PDU CLI access (not a serial console server). Ships with a C19-to-NEMA 5-15P cord and a mounting bracket set. UL/CSA 62368-1 (2nd Ed.) Listed, cTUVus.
16-outlet monitored 2U PDU (SynLink SP series, feature set D). Sixteen IEC C13 outlets on a NEMA L6-30P inlet at 208-240V, protected by 2x2 circuit breakers, with inlet energy metering (V/A/Hz/W/VA/PF/kWh) plus per-outlet and per-circuit monitoring, and no outlet switching. Manage over HTTP/HTTPS, SSH, Telnet, SMTP, SNMP v1/v2/v3, Syslog, REST API, DHCP, NTP, and Ping, with AutoPing alerting, programmable event triggers, and a color LCD that shows power data locally. Two environmental sensor ports (SPA-0010) accept temperature/humidity probes, and an RS-232 (RJ45) serial console server port plus USB-serial (FTDI) give out-of-band access. Centrally managed via the Synaccess Central Management Portal (CMP). Includes a mounting bracket set and quick-start and safety guides. UL/CSA 62368-1:2019 listed, cTUVus.